A1Q9GMA025NA1
1" NPT Female Aluminum
Rate & Totals A1 Series - COMMERICAL GRADE METER
$400.00
Main Specifications
Connection Size: 1"
Connection Type: NPT Female
Flow Range: 0.3 - 3 GPM (1 - 11 LPM)
Pressure Rating: 300 PSI (21 Bar)
Operating Temp With Local Computer: 0 to 140°F (-18 to 60°C) for SAFE AREA ONLY (Non-FM Approved), 0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)
See Catalog Page link to the left
See Catalog Page link to the left
Meter Body Size: 1"
Body Type: Low Flow
Local/Remote Display: Local
Display Type: Digital LCD
Flow Meter Type: A1 Series - COMMERICAL GRADE METER
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Competitor Model Numbers: 03A30GM
Product Type: Rate & Totals
Benefits & Features: 2-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
Max Pressure Drop (at Max Flow in test conditions): 2 PSI
Repeatability (based on test conditions): ± 1.0%
Recommended Strainer Size: 120 Mesh (125 Microns)
Max. Particle Size: .005" / .127 mm
Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt'l]
Accuracy (% of Reading) Factory Calibrated with Computer: Up to ± 5%<br>[Accuracy can vary up to ± 5% depending on installation and fluid type. Field Calibration is recommended for best accuracy.]
Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
Housing Material: Aluminum
Bearings: Ceramic
Shaft: Tungsten Carbide
Rotor: Nylon
Signal Generator: Ferrite
Retaining Rings: 316SS
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Typical K-Factor PPG (PPL): 2200 (581)
Local Module & Output Signal: None
Remote Output: None
Sensor (Pickup): Magnetic
Battery Power: (2) AAA 1.5V Alkaline Battery (2 year)
Frequency Range: 11 - 110 Hz
Totalizing Resets to 0 After Reaching: 99999999
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
Applications (always check Chemical Compatibility Guide): Fuel, Diesel, Petroleum Based Liquids
Not Suitable For Applications: Water
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Line must be full (no air) for proper accuracy
Minimum Straight Pipe Dia.s: 20" Upstream / 5" Downstream
Desired Straight Pipe Dia.s: 40" Upstream / 10" Downstream
Connection to Connection Length (OAL): 4.0" (102 mm)
Shipping Weight (Approximate): 2.0 lbs (0.9kg)
Approvals Notes: See catalog page for full approval specs