G2S10N42GMX 316SS Industrial Flow Meter 1” NPT Display and 4-20mA Output
1" NPT Female
Rate, Totals, 4-20mA & Scaled Pulse Output
$1310.00
Main Specifications
Connection Size: 1"
Connection Type: NPT Female
Flow Range: 5 - 50 GPM (18.9 - 190 LPM)
Operating Temp With Local Computer:
0 to 140°F (-18 to 60°C) for SAFE AREA ONLY (Non-FM Approved)
See Catalog Page link to the left
0 to 140°F (-18 to 60°C) for SAFE AREA ONLY (Non-FM Approved)
See Catalog Page link to the left
Local/Remote Display: Local
Display Type: Digital LCD
Factory Calibrated For: Water like fluids
Product Type: Rate, Totals, 4-20mA & Scaled Pulse Output
Std Calibration Reports Included: Yes
Benefits & Features: Pressure Rated to 1500 PSI; Excellent Chemical Compatibility; Accurate; Durable; 2-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM); 4-20mA Signal & Scaled NPN Open Collector Pulse Output
Max Pressure Drop (at Max Flow in test conditions): 9.7 PSI
Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
Repeatability (based on test conditions): ± 0.1%
Recommended Strainer Size: 120 Mesh (125 Microns)
Max. Particle Size: .005" / .127 mm
Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt'l]
Extended Flow Range: 50 - 75 GPM (190 - 284 LPM)<br>[Accuracy of the extended flow range declines and is not guaranteed]<br>Overranging damages meter and voids warranty
Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
Bearings: 96% Alumina Ceramic/Tungsten Carbide
Shaft: Tungsten Carbide
Rotor: PVDF
Signal Generator: Not Wetted
Retaining Rings: 316SS
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Totalizing Resets to 0 After Reaching: 99999999
Typical K-Factor PPG (PPL): 565 (149)
Sensor (Pickup): Magnetic
Battery Power: (2) AAA 1.5V Alkaline Battery (2 year)
External Power: Required for 4-20mA & Pulse Output
Frequency Range: 47 - 470 Hz
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Line should be kept full (no air) for proper accuracy
Piping Notes: If cavitation affects accuracy, try a flow control valve downstream of meter
Connection to Connection Length (OAL): 4.5" (114 mm)
Shipping Weight (Approximate): 3.0 lbs (1.3 kg)
Approvals Notes: See catalog page for full approval specs