GSCPS-150-RT40
1-1/2" Tri-Clamp 316SS
Rate & Totals, Pulse Out GSCPS Series - PRECISON METER - 3-A APPROVED BODY
$3434.00
Main Specifications
Connection Size: 1-1/2"
Connection Type: Tri-Clamp
Flow Range: 17.7 - 177 GPM
Pressure Rating: Limited by fitting size, clamp and temperature
Operating Temp With Local Computer: -4°F to 176°F (-20°C to 80°C)
[SIP (Up to 1 hour) 285°F (140°C). Remove display, pickup, gaskets & clamps not rated to 285°F]
[SIP (Up to 1 hour) 285°F (140°C). Remove display, pickup, gaskets & clamps not rated to 285°F]
Meter Body Size: 1-1/2"
Body Type: 3-A Approved
Factory Calibrated For: Water like fluids
Flow Meter Type: GSCPS Series - PRECISON METER - 3-A APPROVED BODY
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Local/Remote Display: Local
Display Type: Digital LCD
Product Type: Rate & Totals, Pulse Out
Benefits & Features: The body meets strict 3-A Sanitary Standards using the new "Third Party Verification" (TPV) program; Internals are machined or polished to meet 3-A self-draining and cleaning requirements (Ra32); CIP, SIP, COP; High Accuracy: ± 0.5% (Linearity); Field Serviceable; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
Max Pressure Drop (at Max Flow in test conditions): 14 PSI
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5%
Repeatability (based on test conditions): ± 0.1%
Recommended Strainer Size: 18 Mesh (1000 Microns)
Max. Particle Size: .039" / 1.00 mm
Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
Operating Temp Without Local Computer or With Remote Computer: -100 to 225°F (-74 to 107°C) [Opt'l]
Housing Material: 316SS
Bearings: PEEK
Shaft: 316SS
Thrust Bearings: PEEK
Rotor: CD4MCu Stainless Steel (Nickel Plated)
Rotor Supports: 316SS
Signal Generator: Not Wetted
Retaining Rings: 302SS/316SS
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Local Module & Output Signal: NPN transistor, scalable
Remote Output: (Pulse Out)
Sensor (Pickup): Magnetic
Battery Power: 3.6V Battery (~2 year life)
Totalizing Resets to 0 After Reaching: 99999999
Typical K-Factor PPG (PPL): 342
External Power: Regulated 8-24VDC (Recommended)
Frequency Range: 100 - 1000 Hz (Universal pulse/frequency input compatible with Reed switch, Hall effect, Namur proximity detectors, voltage, current & Coil (15mV P-P min). Max. input frequency 5Khz under external power. The maximum input frequency when not externally powered is 150hz.)
Applications (always check Chemical Compatibility Guide): 3A Approved Food & Beverage, Beer, Wine, Dairy
Piping Notes: If pump, valve, etc. is upstream, need min. 30" Upstream
Minimum Straight Pipe Dia.s: 15" Upstream / 7.5" Downstream
Application Notes: See page 5 in the manual for 3-A Recommended Practices. Unidirectional. The line must be full (no air) for proper accuracy. NOTE: External Power is required for the backlit display and for the meter to function properly at its maximum flow rate. While the display will function under battery power only, the maximum input frequency is too low unless it is externally powered. When maximum flow rates exceed 1 kHz (1000 Hz), external power must be used. See the Frequency Range notes.
Connection to Connection Length (OAL): 4.594" (116.7 mm)
Shipping Weight (Approximate): 10 lbs (4.5 kg)
Approvals Notes: Only the turbine body is 3-A Approved; See catalog page for full approval specs