OM008N513-826R7G
3/8" NPT Female 316LSS
Rate & Totals OM Series - OVAL GEAR
$1210.00
Main Specifications
Connection Size: 3/8"
Connection Type: NPT Female
Flow Range: 4 - 145 GPH (15 - 550 LPH)
Pressure Rating: 1450 PSI (100 Bar)
Operating Temp With Local Computer: 5 to 176°F (-15 to 80°C)
Meter Body Size: 3/8"
Local/Remote Display: Local
Display Type: Digital LCD (GRN Housing)
Flow Meter Type: OM Series - OVAL GEAR
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Product Type: Rate & Totals
Benefits & Features: Excellent for applications with fluctuating or multiple viscosities - No field calibrating required; Accuracy: ± 1% Of Reading; Up to 1,000 cps Viscosity; No straight pipe requirements; Bi-directional; SS Rotors are very stable with increasing temperatures; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Choice of Gallons or Liters; Custom Programmable Display (including UOM); Back-lighted Display when powered externally
Max Pressure Drop (at Max Flow in test conditions): Contact us
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5% @ 3cp
Repeatability (based on test conditions): ± 0.03%
Maximum Viscosity: 1,000 cps
Recommended Strainer Size: 200 Mesh (75 Microns)
Max. Particle Size: .003" / .074 mm
Operating Temp Without Local Computer or With Remote Computer: 5 to 250°F (-15 to 120°C) [Opt'l]
Housing Material: 316LSS
Bearings: Carbon Ceramic
Shaft: Stainless Steel
Rotor: 316SS
Seals: PTFE encapsulated FKM
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Typical K-Factor PPG (PPL): Reed: 1345 (355), Hall Effect: 2690 (710)
Local Module & Output Signal: None (RT40)
Remote Output: None
Battery Power: (1) 3.6V battery (~3 years)
External Power: Regulated 8-24VDC x 50mA minimum
Totalizing Resets to 0 After Reaching: 99999999
Sensor (Pickup): Reed Switch / Hall Effect<br>[Hall Effect Sensor requires dedicated power source]
Applications (always check Chemical Compatibility Guide): Metering clean fluids such as water based liquids for Chemical, Cosmetic, Food, and Pharmaceutical Industries
Not Suitable For Applications: Dirty liquids
Minimum Straight Pipe Dia.s: None
Desired Straight Pipe Dia.s: None
Application Notes: The meter may be mounted horizontally or vertically but must be mounted, so the rotor shafts are in a horizontal plane (see manual), For viscous liquids, the maximum allowable flow may need to be reduced to ensure the pressure drop across the meter does NOT exceed 15 PSI, Viscosities <3cps, min. flow range is 10% of the maximum flow range, Line must be full (no air) for proper accuracy. External Power is required for the backlit display.
Connection to Connection Length (OAL): 2.91" (74mm)
Shipping Weight (Approximate): 7 lbs (3.2 kg)