The Largest IN-STOCK FLOW METER Warehouse + Ships Same Day!

Authorized Distributor of FLOMEC & GPI Flow Meters

QSE10NPT42XXXA Mag Meters 1" MNPT Display & 4-20mA Out

1" NPT Male

Rate & Totals & 4-20mA Output

No longer available.

Main Specifications
Connection Size: 1"
Connection Type: NPT Male
Flow Range: 0.67 - 40 GPM (2.52 - 151 LPM)
Operating Temp With Local Computer: 32° to 140°F (0° to 60°C)
Local/Remote Display: Local
Display Type: Digital LCD
Product Type: Rate & Totals & 4-20mA Output
Benefits & Features: Non-Intrusive, No moving parts to wear out, Low maintenance and repair costs, High Accuracy with quick response time, Can measure with up to 20% solids, Tolerates high flows without damage, Very low pressure drop, Wide turn-down ratio, NIST Reports standard at N/C
Std Calibration Reports Included: Yes - NIST<br>[NIST Certs come with each meter at no extra charge. Please inquire for certificate's date of our stocked meters.]
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5%
Accuracy (% of Reading) Factory Calibrated Body Only: ± 0.5% *
Max. Particle Size: 20% Solids Maximum
Max Pressure Drop (at Max Flow in test conditions): Negligible
Seals: NBR (Non-Wetted)
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Totalizing Resets to 0 After Reaching: 99999999
Typical K-Factor PPG (PPL): 1089
Sensor (Pickup): Electrodes
Battery Power: Requires External Power
External Power: 12-36 VDC
Frequency Range: 10 Hz Minimum - 1,000 Hz Maximum
Remote Output: Optional Remote Display, 4-20mA or Pulse Out (Please contact us)
Piping Notes: Optimal horizontal position: top of meter at 1 or 2 o'clock
Application Notes: Unidirectional. For horizontal or vertical flows. Do not allow liquids to dry or freeze inside of the meter. NOTE: Requires grounding. See Earth Ground Instructions manual.
Connection to Connection Length (OAL): 11.00" (279.4mm)
Shipping Weight (Approximate): 5 lbs (2.3 kg)
Approvals Notes: IP67, CE, CSA