TM10NQ9GMA PVC Water Flow Meter 1” NPT
1" NPT Female PVC
Rate & Totals TM Series - WATER METER
$476.00
Main Specifications
Connection Size: 1"
Connection Type: NPT Female
Flow Range: 5 - 50 GPM (19 - 190 LPM)
Pressure Rating: 225 PSI @ 73°F, 49 PSI @ 140°F
Operating Temp With Local Computer: 32°F to 140°F (0°C to 60°C)
Do not allow to freeze
Do not allow to freeze
Meter Body Size: 1"
Body Type: Sch 80
Local/Remote Display: Local
Display Type: Digital LCD
Factory Calibrated For: Water like fluids
Flow Meter Type: TM Series - WATER METER
Std Calibration Reports Included: No
Warranty Period: 1 Year
Product Type: Rate & Totals
Benefits & Features: 2-Year Battery Powered, 6 Digit Display - Floating Decimal, Rate of Flow, Batch & Cumulative Totals, Factory Calibrated and Field Calibratable, User configurable for Unit Of Measure, such as GPM, LPM and more, Custom Programmable Display (including UOM)
Accuracy (% of Reading) Factory Calibrated with Computer: ± 3.0%
Recommended Strainer Size: ~120 Mesh (125 Microns)
Operating Temp Without Local Computer or With Remote Computer: 32 to 140°F (0 to 60°C) [Opt'l]
Housing Material: PVC
Bearings: Ceramic
Shaft: Tungsten Carbide
Rotor: PVDF
Signal Generator: Not Wetted
Retaining Rings: 316SS
Display Function: Rate, Velocity, 2 Totals (1 Resettable, 1 Cumulative)
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Local Module & Output Signal: None
Remote Output: None
Sensor (Pickup): Magnetic
Battery Power: (2) AAA 1.5V Alkaline Battery (2 year)
External Power: Optional
Frequency Range: 0.25 Hz - 3 kHz
Totalizing Resets to 0 After Reaching: 99999999
Typical K-Factor PPG (PPL): 565 (149)
Applications (always check Chemical Compatibility Guide): Waste Water, Water Treatment, Sub-Metering, Water Based Cooling Systems
Not Suitable For Applications: Fuels, Oils, DI Water, Freezing Medias
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Accuracy can be improved with field calibration, Line must be full (no air) for proper accuracy, Do not allow fluid to freeze inside meter
Minimum Straight Pipe Dia.s: 10" Upstream / 5" Downstream
Piping Notes: Not recommended to connect to metal piping. A strap wrench is recommended for installation, otherwise housing will crack if overtightened. If cavitation affects accuracy, try a flow control valve downstream of the meter.
Connection to Connection Length (OAL): 6.6" (167 mm)
Shipping Weight (Approximate): 1.1 lbs (0.5 kg)
Approvals Notes: See catalog page for full approval specs