TM30NP9GMD PVC Water Flow Meter 3” NPT Display and Pulse Out
3" NPT Female
Rate, Totals, & Scaled Pulse Output
Main Specifications
Connection Size: 3"
Connection Type: NPT Female
Flow Range: 40 - 400 GPM (151 - 1514 LPM)
Operating Temp With Local Computer: 32°F to 140°F (0°C to 60°C)
Do not allow to freeze
Do not allow to freeze
Body Type: Sch 80
Local/Remote Display: Local
Display Type: Digital LCD
Factory Calibrated For: Water like fluids
Product Type: Rate, Totals, & Scaled Pulse Output
Std Calibration Reports Included: No
Benefits & Features: 2-Year Battery Powered, 6 Digit Display - Floating Decimal, Rate of Flow, Batch & Cumulative Totals, Factory Calibrated and Field Calibratable, Replaceable Turbine Assembly, User configurable for Unit Of Measure, such as GPM, LPM and more, Custom Programmable Display (including UOM); Scaled Pulse Output
Accuracy (% of Reading) Factory Calibrated with Computer: ± 3.0%
Operating Temp Without Local Computer or With Remote Computer: 32 to 140°F (0 to 60°C) [Opt'l]
Extended Flow Range: 30 - 40 GPM, 400 - 600 GPM<br>(Accuracy: ± >5% Full Scale)<br>Overranging damages meter and voids warranty
Bearings: PEEK
Shaft: Stainless Steel
Thrust Washers: Stainless Steel
Rotor: Acetal
Nose Cone: Acetal
Signal Generator: Ferrite
Display Function: Rate, Velocity, 2 Totals (1 Resettable, 1 Cumulative)
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Totalizing Resets to 0 After Reaching: 99999999
Typical K-Factor PPG (PPL): 43 (11)
Sensor (Pickup): Magnetic
Battery Power: (2) AAA 1.5V Alkaline Battery (2 year)
External Power: Required for Pulse Output
Frequency Range: 0.25 Hz - 3 kHz
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Accuracy can be improved with field calibration, Line must be full (no air) for proper accuracy, Do not allow fluid to freeze inside meter
Piping Notes: Not recommended to connect to metal piping. A strap wrench is recommended for installation, otherwise housing will crack if overtightened. If cavitation affects accuracy, try a flow control valve downstream of the meter.
Connection to Connection Length (OAL): 14.7" (373 mm)
Shipping Weight (Approximate): 6.7 lbs (3.1 kg)
Approvals Notes: NSF/ANSI 61 & 372. See catalog page for full approval specs.<br><br> (Meters manufactured after 1/1/2023 will not carry the NSF Certification. Meters manufactured before 1/1/2023 are NSF Certified but will not be listed on the NSF website)