TM30NPOXXD PVC Water Flow Meter 3” NPT Pulse Out Only
3" NPT Female
Pulse Out
$1138.00
Main Specifications
Connection Size: 3"
Connection Type: NPT Female
Flow Range: 40 - 400 GPM (151 - 1514 LPM)
Operating Temp With Local Computer: 32°F to 140°F (0°C to 60°C)
Do not allow to freeze
Do not allow to freeze
Body Type: Sch 80
Local/Remote Display: Pulse Out Only - No Display
Display Type: Pulse Out Only - No Display
Factory Calibrated For: Water like fluids
Product Type: Pulse Out
Benefits & Features: 2-Year Battery Powered
Std Calibration Reports Included: No
Operating Temp Without Local Computer or With Remote Computer: 32 to 140°F (0 to 60°C) [Opt'l]
Extended Flow Range: 30 - 40 GPM, 400 - 600 GPM<br>(Accuracy: ± >5% Full Scale)<br>Overranging damages meter and voids warranty
Bearings: PEEK
Shaft: Stainless Steel
Thrust Washers: Stainless Steel
Rotor: Acetal
Nose Cone: Acetal
Signal Generator: Ferrite
Typical K-Factor PPG (PPL): 43 (11)
Sensor (Pickup): Magnetic
Battery Power: None
External Power: Requires 5VDC to 26VDC
Frequency Range: 0.25 Hz - 3 kHz
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Accuracy can be improved with field calibration, Line must be full (no air) for proper accuracy, Do not allow fluid to freeze inside meter
Piping Notes: Not recommended to connect to metal piping. A strap wrench is recommended for installation, otherwise housing will crack if overtightened. If cavitation affects accuracy, try a flow control valve downstream of the meter.
Connection to Connection Length (OAL): 14.7" (373 mm)
Shipping Weight (Approximate): 6.7 lbs (3.1 kg)
Approvals Notes: NSF/ANSI 61 & 372. See catalog page for full approval specs.<br><br> (Meters manufactured after 1/1/2023 will not carry the NSF Certification. Meters manufactured before 1/1/2023 are NSF Certified but will not be listed on the NSF website)